2022-08-17 13:24:54

How to quickly and effectively replace the air compressor lubricating oil

Many people say that the routine maintenance of an air compressor is very similar to that of a car, but there are still some differences between the two in actual operation. For example, when replacing the lubricating oil in a car, it only needs to be drained and added, while the replacement of lubricating oil by an air compressor is There are certain requirements and operation steps. Today, Xiaobian will show you how to properly replace the lubricating oil.


1. Turn on and run to normal temperature for one hour;


2. Shut down;


3. Drain the oil from the tank, cooler and all filters;


4. Add the newly replaced oil to the minimum oil amount required for operation (eg: 1/2 volume);


5. Turn on and run to normal operating temperature for one hour. During the hour, open and close the exhaust valve every 15 minutes to cycle the machine at the highest and lowest pressure valve settings;


6. Shut down;


7. Drain the oil from the cooler, oil tank and all filters;


8. Add the newly replaced oil to 1/2 volume;


9. Turn on and run to normal operating temperature for one hour. During the hour, open and close the exhaust valve every 15 minutes to cycle the machine at the highest and lowest pressure valve settings;


10. Shut down;


11. Drain the oil from the entire machine, including the cooler, oil tank and filter. Remove pipes if necessary to remove low oil. Clean screen, replace separator and all non-permanent oil filters. Check that the inlet filter is covered by contaminated oil, and replace it as appropriate;


12. Add the recommended oil to be replaced to the minimum oil amount required for operation;


13. Power on and run to normal temperature for 15 minutes;


14. Shut down and drain the oil in the machine. Open the filter and filter screen, but do not need to replace;


15. Add the oil you recommend to the machine to the normal oil level;


16. Restart the machine and pay attention to the oil level. When the machine is operating, there will be about 1/2 oil in the observation window;


17. The foam can be dispersed to the oil level within 2 minutes after shutdown and no oil will flow out of the drain valve.