2024-07-16 13:49:46

Reasons for low pressure of screw air compressor unit

When we use screw air compressors in our daily life, we can't avoid encountering various problems. Today, we will discuss the problem of low pressure of screw air compressor units with you. I hope that through this article, everyone will have a new understanding of the reasons for low pressure of screw air compressor units.


1. The actual gas consumption is greater than the output gas volume of the unit


2. The exhaust valve is faulty (cannot be closed during loading)


3. The intake valve is faulty


4. The transmission system is abnormal, the ambient temperature is too high, and the air filter is blocked


5. Load solenoid valve failure


6. The minimum pressure valve is stuck


7. The pipeline may leak


8. The pressure setting is too low


9. Pressure sensor failure


10. Pressure gauge failure (relay control unit)


11. Pressure switch failure


12. The pressure sensor or pressure gauge input hose is leaking