2024-10-23 15:47:48

Reasons for insufficient heat dissipation of permanent magnet variable frequency air compressor

We all know that in the daily use of permanent magnet variable frequency screw air compressor, various problems are often encountered, among which insufficient heat dissipation of permanent magnet variable frequency air compressor affects work efficiency. Below, the editor will share with you some important factors about why permanent magnet variable frequency air compressor has insufficient heat dissipation:


Environmental factors often have a great impact on the ventilation and heat dissipation status. There are three important factors affecting the heat dissipation of the surrounding environment of permanent magnet variable frequency air compressor: the partition wall or other obstacles between the permanent magnet variable frequency air compressor are too close; there may be other heat sources near the permanent magnet variable frequency air compressor. For this reason, it is recommended to strictly follow the installation and use environment requirements of permanent magnet variable frequency air compressor to install and use permanent magnet variable frequency air compressor.


Radiator blockage will also cause corresponding problems. Because when there is a lot of dust around the permanent magnet variable frequency air compressor, it will cause a layer of dust or sludge to adhere to the surface of the radiator due to long-term operation, which will affect the heat dissipation effect. A dirty oil filter may also cause a certain degree of overheating of the permanent magnet variable frequency air compressor. Because the oil filter of the permanent magnet variable frequency air compressor is too dirty, the oil cannot enter the permanent magnet variable frequency air compressor at a normal flow rate, which will cause the permanent magnet variable frequency air compressor to heat up rapidly due to lack of cooling oil. Of course, there is also the cooling oil level is too low. It is recommended to regularly maintain and maintain the permanent magnet variable frequency air compressor to prevent the above situation from happening.


If the oil grade is low or the oil quality is poor, there will be corresponding problems. The permanent magnet variable frequency air compressor should use the manufacturer's original special permanent magnet variable frequency air compressor oil. If other low-grade or inferior oils are used, the viscosity and specific heat may not meet the standard, causing the temperature to be too high.